Most Energy Efficient Dual Quality Water Architecture for Municipal & Industrial Water Supply

Our gravity purifier produces clarified water that meets municipal standard directly, split into two independent water streams without extra membrane polishing: Utility Water & Direct Drinking Water.

• Total Scale:1.2 M m³/day Max Customized Capacity
• NF Operating Pressure:7 bar (vs RO 15 bar)
• Core Advantage:Zero Electricity for Main Purification
• Blended OPEX:0.19 RM/m³ (Customized by Raw Water)
What is Dual Quality Water Supply System?

The Dual-Quality Water Supply System is an integrated split-stream water treatment solution independently developed by QILEE, combining zero-power Gravity Purifier and modular Skid-Mounted Nanofiltration (NF) equipment. Instead of treating all water to drinking standard with high energy consumption, the system divides clarified water into two pipelines for classified supply:

Stream 1 Utility Water
For daily miscellaneous use & industrial production, no post treatment, zero extra energy loss.
Capacity: Customized up to 900,000 m³/day

Process: Gravity clarified water direct distribution

Standard: Local Municipal Water Standard (e.g. Malaysia SPAN)

Feature: Zero additional energy, no chemical dosing after clarification
Stream 2 Direct Drinking Water
Deep treated by skid NF units, selectively retains beneficial minerals Ca²⁺, Mg²⁺, no remineralisation required.
Capacity: Customized up to 300,000 m³/day

Process: Skid Mounted NF at 7 bar low pressure

Standard: WHO 4th Edition Drinking Water Standard

Feature: Retain natural Ca²⁺, Mg²⁺; remove salts, colour, pathogens
Core Competitive Advantages
The Gravity Purifier core operates with zero electricity. Low pressure 7 bar NF cuts membrane energy cost versus 15 bar RO. Utility water skips secondary membrane treatment to eliminate extra power waste.
NF skid units deliver 500 m³/hr each, scalable up to 32 sets. Factory pre‑assembly enables fast site installation, easy maintenance. Gravity Purifier arrays flexibly combine units to match varying project capacity demands.
Nanofiltration removes harmful salts, turbidity and pathogens. It keeps healthy Ca²⁺ and Mg²⁺, maintaining stable hardness. No extra mineral adding step is needed for qualified direct drinking effluent water.
Split stream supply removes full‑flow deep membrane work to reduce CAPEX. Blended OPEX can reach 0.19 RM/m³ subject to raw water quality. Long life gravity equipment keeps routine maintenance expenses very low.
Design Basis & Water Quality Standard
Parameter Unit Raw Water Influent Range Utility Water Limit Direct‑Drinking Water Limit
Turbidity NTU 10‑1,000 ≤ 1 < 0.2
TSS mg/L 20‑800 ≤ 5 ≤ 5
TDS mg/L 150‑500 ≤ 200
pH 6.5‑7.5 6.5‑8.5 6.5‑8.5
Total Hardness mg/L as CaCO₃ 60‑180 60 ‑ 100 (NF‑retained natural mineral)
Iron / Manganese mg/L ≤1.5 / ≤0.5 ≤ 0.1 / ≤ 0.05 ≤0.1 / ≤0.05
Colour Hazen 10‑60 ≤ 5 ≤ 5
Coliforms CFU/100mL < 10⁴ 0
Standard Remark
Direct Drinking Water Compliance: WHO 4th Edition Drinking Water Standard
Utility Water Compliance: Local Municipal Standard (e.g. Malaysia SPAN)

For Wastewater / Industrial Effluent Applications

Raw Water Intake
Dam / River / Mountain Source
Pre-treatment
Drum Screen + PAC & PAM Dosing System
Integrated Gravity Purifier
Zero Electricity Core Unit
Clarified Water Reservoir
Effluent Turbidity
utility distribution pumps (24 × VSD CNP Pumps) → utility delivery (Households & Industry)
NF skid system (32 skids × 500 m³/hr, 7 bar) → direct-drinking delivery
Overall Site Layout & Three Functional Zones
Zone 1: Pre Treatment Area
• Function: Raw water interception, large impurity filtration, coagulant dosing
• Main Equipment: Drum screen, chemical storage tanks, PAC/PAM automatic dosing unit
Zone 2: Gravity Purifier Core Area
• Function: Zero power clarification, core water purification unit
• Main Equipment: 250-unit gravity purifier array, fully gravity-driven without electricity
• Effluent Index: Turbidity stable below 1 NTU, meet municipal utility standard
Zone 3: Dual Stream distribution zone
• Zone 3A: Uutility water building
• Output: 900,000 m³/day max miscellaneous water, VSD pump distribution system
Zone 3B: NF skid compound
• Output: 300,000 m³/day max direct drinking water, modular nanofiltration skid units
Core Equipment Introduction
  Gravity Purifier (Zero Electricity Core Unit)
• Running Principle: Full gravity sedimentation & filtration, no electric pump inside
• Matching Capacity: Combined array for 1.2 M m³/day total water yield
• Output Standard: Clarified water turbidity ≤1 NTU, directly supply utility pipeline
• Advantage: Low operation cost, no power consumption, simple maintenance
  Skid Mounted NF Direct-Drinking System
• Single Skid Capacity: 500 m³/hr per set, max 32 skids combined
• Operating Pressure: 7 bar (vs traditional RO 15 bar, energy saving)
• Membrane Performance: Selectively retain Ca²⁺, Mg²⁺; remove colour, salt, pathogenic bacteria
• Installation Feature: Fully skid-mounted, factory pre-installed, fast delivery & commissioning
Tell Us More About Your Project !
If you have any questions about water treatment systems, please feel free to contact QILEE.
  Stable equipment
  Mature technology
  Automated operation
  Simple operation

Please leave us a message with any questions.

Contact Us

Tel: +86 13370035529

Business What's App: +86 13636655908

E-mail: qilee@qileegroup.com

Add: No. 351 Wenqu Road, Fengxian District, Shanghai

Your trusted Water Treatment System Partner
Copyright © 2026 Shanghai QILEE Environmental Protection Equipment Co., Ltd | Sitemap
Customer service
detect