At dawn, the Chlorine Dosing Pump 2-4900L/h for Water Treatment Plant hums to life, a quiet guard in the treatment room. It meters chlorine with fine care across 2 to 4,900 L/h—strong, precise, and built to last. Operators watch clear, safe water flow out and feel calm — low fuss, high trust, your steady partner for clean water.

5.0
shipping:
Ocean freight
brand name:
QILEE
model number:
MB0250SN/1.M.N
Payments:
L/C,D/A,D/P,T/T,Western Union,MoneyGram,OA
Place of Origin:
China
design customization

    oops...!

    no product data.

    Go to homepage
    Speed
    149SPM
    voltage
    220V/380V
    power source
    Electric
    outlet size
    1/2
    customized support
    OEM
    application
    Automotive Industry, Industrial Utilities, Pharmaceutical Industry, Wastewater Transport And Flood Control, Wastewater Treatment, Water Distribution, Water Treatment Solutions
    Ball check material
    Glass;Ceramic;316SS
    Diaphragm material
    PTFE
    LE material
    PP;PVC;PVDF;316SS
    Motor Power
    0.25KW
    Flow rate
    9.5L/H
    Power
    0.25KW
    structure
    Diaphragm Pump
    Pressure
    10bar
    Product name
    dosing pump
    place of origin
    Shanghai, China

    Precise, Durable, Compact Dosing 

    Ensure safe, accurate disinfection and chemical control in water treatment with the Chemical Dosing Pump's wide 2–4900 L/h range and ±2% dosing accuracy, capable of handling temperatures up to 45°C and viscosities up to 1200 cP. Corrosion‑resistant liquid ends (PP/PVC/PVDF/316SS), PTFE diaphragm, self‑cleaning check valves and a robust worm‑gear drive deliver leak‑free, long‑term reliability with hypochlorite, acids or high‑viscosity fluids. Compact, service‑friendly styling with manual, electric stroke and frequency inverter controls, shipped in standard export cartons with 3–20 day delivery for fast, high‑quality deployment.

    1620183233g0e
    1620183233oxz

    Precise High Capacity Chlorinator

    This Chemical Dosing Pump for chlorine dosing in water treatment plants delivers 2–4900 L/h flow with up to 10 bar discharge pressure, ±2% dosing accuracy and a 10:1 turndown ratio while handling liquids to 45°C and viscosities up to 1200 cP. It is engineered for municipal tap water, swimming pools, urban sewage and industrial effluent applications—performing pH adjustment, flocculation, polymer and hypochlorite dosing—with corrosion-resistant liquid end options (PP, PVC, PVDF, 316SS), PTFE diaphragms and leak-proof valve seats for dependable chemical compatibility and operational value. Structural advantages include self-cleaning check valves, variable eccentric stroke adjustment, sliding bearings and wear-resistant worm gears, plus manual, electric stroke controller and frequency inverter options to ensure smooth, precise, long-term performance.

    Reliable Chlorine Dosing Pump 

    The Chlorine Dosing Pump 2-4900L/h for water treatment plant is a robust Chemical Dosing Pump engineered for municipal tap water, swimming pools, urban sewage and industrial effluent disinfection with hypochlorite. It delivers 2–4900 L/h at up to 10 bar with a 10:1 turndown ratio and ±2% accuracy, and its liquid end options (PP, PVC, PVDF, 316SS), PTFE diaphragm and self‑cleaning check valves ensure leak‑free handling of corrosive or high‑viscosity fluids. Variable eccentric stroke adjustment, a durable worm‑gear drive and optional electric stroke controller or frequency inverter enable smooth pulsation control and external 4–20 mA integration for reliable automated dosing.


    ◎  

    ◎ 

    ◎ 

    16201832330io
    1620183233rje

    Precise Reliable High Capacity

    Born from decades of water-treatment engineering, the Chlorine Dosing Pump 2-4900L/h for water treatment plants pairs precision manufacturing with corrosion-resistant materials to ensure dependable, long-life performance. As a Chemical Dosing Pump it delivers variable flow control, accurate stroke adjustment, digital metering and leak-proof sealing with built-in alarms for blockages or low supply to guarantee stable chlorine dosing and regulatory compliance. Compact modular construction, energy-efficient drives, wide flow range and IP65 protection minimize downtime, simplify maintenance and reduce total operating costs while ensuring safe, consistent disinfection.

    Material introduction

    The Chemical Dosing Pump features a corrosion‑resistant liquid end offered in PP, PVC, PVDF or 316 stainless steel to safely handle chlorine, hypochlorite and other aggressive chemicals. A PTFE diaphragm and selectable glass, ceramic or 316SS ball checks, together with specially designed valve seats, provide chemically inert wetted paths and reliable, leak‑free operation. The drive unit uses sliding bearings and high‑strength, wear‑resistant worm gears in a robust housing to withstand pulsation impact and harsh water‑treatment conditions.


    ◎ Corrosion-Resistant Liquid End 

    ◎ Sealing & Check Components

    ◎ Drive & Mechanical Assembly

    1620183233lpr

    FAQ

    1
    What types of chlorine chemicals and concentrations can the Chlorine Dosing Pump 2–4900 L/h handle?
    This pump is intended for liquid chlorine disinfectants commonly used in water treatment, such as sodium hypochlorite (liquid bleach) and other liquid chlorine solutions. Compatibility depends on the wetted materials (e.g., PVDF, PTFE, stainless steel) and chemical concentration — typical water-treatment concentrations (household to industrial-strength hypochlorite) are handled, but gaseous chlorine requires dedicated gas feed systems and is not suitable unless the specific model is rated for it. Always check the pump’s chemical-compatibility chart and the chemical manufacturer’s MSDS before use.
    2
    What flow/dosing range and accuracy should I expect from this pump in real applications?
    The model range covers from very low dosing up to 2–4900 L/h, allowing use from small dosing tasks to large plant-scale disinfection. Actual dosing accuracy depends on model, set-up and maintenance; when installed and calibrated correctly you can expect stable dosing within a typical process tolerance (manufacturer specs often quote accuracies around ±1–5%). Use stroke/volume or frequency controls and calibrate on-site (gravimetric or volumetric test) for best results.
    3
    How should the pump be installed in a water treatment plant (piping and electrical considerations)?
    Mount the pump on a firm, level base near the chemical tank. Use an appropriate suction line with foot valve and strainer to prevent air ingress; minimize suction lift within the pump’s rated limit. Fit a non-return/check valve and injection quill at the dosing point (downstream of any static mixer or point where turbulent mixing occurs). Ensure piping and fittings are chemically compatible and sized to the pump’s ports. Electrically, provide the correct supply voltage, proper grounding and overload protection. If using remote control, wire the 4–20 mA / pulse / start-stop inputs to your control system per the wiring diagram. Observe maximum inlet/outlet pressures and install pressure relief or bypass if required.
    4
    What routine maintenance and troubleshooting steps are recommended for reliable operation?
    Regular checks extend pump life and accuracy: daily visual inspection for leaks, weekly check/clean suction strainers and injection points, monthly inspect diaphragms, valves and seals for wear and replace as needed. Keep spare diaphragms, valve seats and O-rings on hand. Common troubleshooting: low flow usually caused by air in suction line, clogged strainer or failed check valve; pulsation may indicate missing pulsation dampener or worn valve; irregular dosing often caused by electrical/control issues or worn diaphragm. Follow the manufacturer’s maintenance schedule and only use recommended spare parts.
    5
    Which water-treatment applications is this pump best suited for?
    The pump is suitable for a wide range of dosing tasks in water treatment: potable water disinfection at municipal plants, wastewater and sewage disinfection, industrial process water treatment, cooling tower/chiller system chlorination, and commercial swimming-pool treatment. It’s useful wherever controlled dosing of liquid chlorine is required. Confirm local regulatory requirements for potable water and wastewater disinfection when selecting materials and control options.
    6
    What safety precautions are essential when using chlorine dosing pumps?
    Treat chlorine solutions as hazardous chemicals: use appropriate PPE (chemical-resistant gloves, goggles/face shield, apron), ensure good ventilation where chemicals are stored or mixed, have emergency eyewash and shower access, and use secondary containment for chemical tanks. Never mix chlorine solutions with acids or incompatible chemicals. Train operators on handling and spill response, keep MSDS accessible, and install leak detection or alarms if required. For gaseous chlorine or large-scale systems consult specialist safety standards and use equipment specifically rated for that application.
    Tell Us More About Your Project !
    If you have any questions about water treatment systems, please feel free to contact QILEE.
      Stable equipment
      Mature technology
      Automated operation
      Simple operation

    Do You Have any Questions? Welcome to Leave Us a Message.

    Related Products
    no data
    Contact Us

    Tel: +86 13370035529

    Business What's App: +86 13636655908

    E-mail: qilee@qileegroup.com

    Add: No. 351 Wenqu Road, Fengxian District, Shanghai

    Your trusted Water Treatment System Partner
    no data
    Copyright © 2026 Shanghai QILEE Environmental Protection Equipment Co., Ltd | Sitemap
    Customer service
    detect