Choosing an evaporator starts with understanding your wastewater constituents and what you need the system to do. You should look at the wastewater volume, what it contains, how many hours the plant runs, and which utilities are available. Site space also matters. You need to decide whether the main goal is to reduce waste volume, recover water for reuse, or do both. We offer all three options through our evaporator range, including the MVR multi-effect evaporator. The right choice depends on the project’s real operating conditions.
An MVR (Mechanical Vapor Recompression) evaporator is a suitable choice when energy savings are important. It takes the vapor made during evaporation, compresses it, and uses it again as a heat source. This means the system needs less outside energy. It works well for larger plants with a steady wastewater flow. It is useful when a facility wants to concentrate wastewater and reduce the amount sent for further treatment. Before choosing MVR, the wastewater should be checked for scaling, solids, and changing loads.
A multi-effect evaporator is a suitable choice when heat can be reused in several stages. In this system, the vapor from one stage heats the next stage. We offer double-effect, triple-effect, and larger multi-effect systems. Using more stages can reduce energy use compared with a single-effect system. However, more stages also mean more things to control. The number of stages should match the available temperature difference and the site’s operating conditions.
A vacuum heat pump evaporator is designed for smaller and medium-sized facilities. It is suited to sites with low wastewater flow, limited space, or a need for straightforward operation. It uses heat-pump technology and vacuum conditions to evaporate water at a low temperature. We position this system for SMEs that want to reduce wastewater volume and recover clean water for reuse. We report energy savings of more than 90% for this option. If the recovered water will be reused, it needs extra filtration or a reverse osmosis system.
Before we recommend an option, we need key project information. This includes flow rate, pollutants, solids, scaling risk, reuse or discharge targets, and available utilities. The best system is not always the cheapest one to buy. It is the one that meets the treatment goal and can run reliably over time.
Zero Liquid Discharge, or ZLD, is a wastewater management approach. Its goal is to prevent the routine discharge of liquid wastewater from an industrial facility. Instead of releasing treated water into the environment, the system recovers as much reusable water as possible. The remaining contaminants are concentrated into a smaller waste stream. This concentrated residue can then be processed into solid material for proper handling and disposal. ZLD is especially relevant for industries with high-salinity wastewater or limited water and discharge options.
Achieving ZLD usually needs several treatment stages. It cannot rely on one piece of equipment. The process may start with physical and chemical treatment. This removes suspended solids, oils, organic matter, and other substances that could affect downstream equipment. Membrane technologies such as nanofiltration and reverse osmosis can then recover more water. They also concentrate dissolved salts. The remaining concentrated brine can be sent for further treatment. The right steps depend on its composition and concentration.
We support ZLD projects by combining membrane separation, brine concentration, crystallization, and evaporation technologies. Our water treatment technology portfolio includes these integrated treatment approaches. Reverse osmosis can be part of the first water recovery stage when feed-water conditions are suitable. As the brine becomes more concentrated, a brine concentrator or evaporator can recover more water. This reduces the remaining liquid volume. Crystallization can then separate dissolved salts from the concentrated solution. This creates solid residues for proper management. The exact process depends on the wastewater, salt content, and required recovery level.
We also offer evaporation technologies for different ZLD needs. These include MVR, multi-effect evaporators, and vacuum heat pump evaporators. Each option has different energy and operating characteristics. The right choice depends on the volume and composition of the concentrated wastewater. Chemical dosing and pretreatment may also be needed. These steps help manage scaling, fouling, and other operating problems. Combining these processes creates a more complete water purification process for facilities that want to reduce liquid waste.
A well-designed ZLD system can increase water recovery. It can also reduce wastewater discharge and improve the handling of concentrated industrial waste. However, ZLD needs careful planning. Energy use, chemical needs, residue handling, and operating costs all matter. Not every wastewater stream needs the same setup. Hence, we consider the feed-water characteristics, expected recovery rate, site conditions, and environmental requirements. The goal is to recover reusable water. At the same time, the remaining concentrated and solid residues must be properly managed.
We offer containerized water treatment systems and industrial wastewater treatment systems in different capacities. These systems serve municipal, industrial, commercial, and remote-site projects. The capacity depends on the product line, the technology used, and the quality of the incoming water. We do not use one fixed capacity for every system. Instead, we develop a configuration based on each project’s needs. Several units or containers can also be combined when more capacity is needed.
For industrial wastewater treatment, we list a capacity range of about 10–100 m³/h. Custom options are available based on project needs. These systems can include dissolved air flotation, chemical dosing, MBR, TMBR, nanofiltration, and reverse osmosis. The treatment steps depend on the pollutants in the wastewater and the required treated-water quality. Several containers can be combined for larger industrial projects that need more capacity.
For domestic sewage treatment, our containerized A/O-MBR equipment has a published capacity of 30–100 m³/day for one integrated container. When more capacity is needed, several units can be combined. This can serve applications from about 100–1,000 m³/day. These systems are used for decentralized sewage treatment. Common users include rural communities, resorts, islands, and other sites without easy access to a municipal sewer network.
We also offer containerized systems for water purification and industrial water production. Our standard surface-water purification series covers about 20–100 m³/h. Our brackish-water reverse osmosis series covers 5–50 m³/h. The seawater reverse osmosis series covers about 5–20 m³/h. The ultrafiltration series covers 30–100 m³/h. Our UF+RO high-purity water systems have a design capacity of 5–50 m³/h. These systems can be used for drinking water production, desalination, and industrial water supply.
Choosing the right capacity is not only about daily water demand. We also need to consider wastewater composition, peak flow rates, operating hours, and contaminant levels. The required discharge or reuse standard is also important. Available space, power supply, and other site utilities can affect the final setup.
Customers should provide a water analysis and expected treatment volume when asking for a quotation. This helps us recommend the right system size. It avoids choosing a system that is too large or too small for the project.
MBR and UF+RO are two different ways to recover water for reuse. Both use membrane technology, but they do different jobs. MBR combines biological wastewater treatment with membrane separation. UF+RO uses physical filtration and membrane desalination to remove different contaminants. The right choice depends on the incoming wastewater and the quality needed for reuse.
MBR is useful when wastewater has high levels of organic matter and suspended solids. In an MBR system, microorganisms break down biodegradable pollutants. The membrane then separates treated water from the biological sludge. This replaces the normal secondary sedimentation stage. It also helps produce effluent with low suspended solids. We offer MBR-based containerized reclaimed-water systems for municipal sewage and industrial wastewater. Depending on the water quality and reuse goal, the treated water may be suitable for irrigation, cleaning, and selected industrial processes.
UF+RO uses two membrane stages. First, ultrafiltration removes suspended particles, colloids, and microorganisms. These particles could affect downstream equipment. The water then passes through reverse osmosis membranes. RO reduces dissolved salts and many other dissolved contaminants. This makes UF+RO suitable for higher-quality water needs. It can be used for industrial process water and selected high-purity water applications. We offer containerized UF+RO systems for municipal and industrial water treatment and reuse.
The main difference is the treatment goal. MBR focuses on breaking down organic pollutants and separating biomass. UF+RO focuses on physical separation and reducing dissolved substances. An MBR system may be enough when the reuse application does not require major dissolved-solids removal. However, extra membrane treatment may be needed when the water has high salt levels or must meet stricter quality standards.
The two systems can also be used together. They are not always competing options. For example, MBR can provide biological treatment first. UF and reverse osmosis can then polish the water further. This depends on the wastewater characteristics and the required reuse quality.
Our integrated water technologies allow different processes to be combined. The final choice should consider feed-water quality, recovery targets, operating costs, and the intended reuse application. This helps ensure the selected water purification process meets the required quality. It also avoids adding treatment steps that are not needed.
Our Integrated Chemical Process System is a compact, modular system for chemical preparation, dosing, and monitoring. We design it for facilities that need accurate and steady chemical addition during water purification and wastewater treatment. The system can be used in tap water treatment, cooling towers, boiler water treatment, and sewage treatment. It brings several chemical handling and control functions into one unit. This makes chemical treatment easier to manage.
The system includes dissolution and dilution tanks, variable-speed mixers, precision metering pumps, online monitoring sensors, and a programmable logic controller. It also includes a 7-inch human-machine interface. These parts work together to prepare chemicals at the right concentration. They then add controlled amounts of chemical into the treatment process. The chemicals used depend on the application. They can include coagulants, disinfectants, scale and corrosion inhibitors, oxygen scavengers, flocculants, denitrifying agents, and heavy-metal chelators. The system can be configured based on flow rate, chemical type, and the plant’s existing controls.
Another important feature is monitoring and dosing control. Online sensors measure turbidity, pH, ORP, conductivity, hardness, and COD. These readings help the control system adjust chemical dosing as water conditions change. We state that the system can achieve dosing accuracy of about plus or minus 1%. It also includes data logging, alarms for low chemical levels and pump overload, and touchscreen controls. These features help operators monitor system performance.
The modular design makes the system flexible. We can add it to an existing treatment facility. We can also supply it as a standalone skid or containerized unit. The system can communicate with plant control systems through MODBUS and PROFINET. We state this setup can reduce chemical use, improve dosing consistency, and simplify installation. We also report possible reductions in chemical use of 12–20% and energy use of about 15%, depending on the operating conditions.
For facilities with complex water treatment needs, accurate chemical preparation is important. It helps produce consistent treatment results. Our system can support coagulation, disinfection, pH adjustment, and heavy-metal removal. It can also work with filtration and membrane technologies in a wider industrial water purification system. The final setup depends on the water quality, treatment goals, and chemicals needed at the facility.
A/O-MBR and A²/O-MBR are two biological wastewater treatment systems. Both combine biological treatment with membrane bioreactor technology. They are designed to treat domestic sewage. They reduce organic pollutants and suspended solids in the treated water. The main difference lies in the arrangement of the biological stages and in how they remove nutrients. This difference helps customers choose the right containerized wastewater plant.
The A/O-MBR process uses an anoxic stage and an aerobic stage with membrane filtration. In the anoxic stage, microorganisms help turn nitrate into nitrogen gas. This process is called denitrification. In the aerobic stage, microorganisms break down organic matter. Nitrifying bacteria also convert ammonia nitrogen into nitrate. The MBR membrane then separates treated water from biological sludge. This helps produce clear effluent with low suspended solids. Our QL-AOMBR series is designed for decentralized domestic sewage treatment.
The A²/O-MBR process adds an anaerobic stage before the anoxic and aerobic stages. This creates three biological environments: anaerobic, anoxic, and aerobic. The anaerobic stage supports biological phosphorus removal. It encourages phosphorus-accumulating organisms to release phosphorus. In the later stages, these organisms take up phosphorus under the right conditions. The anoxic and aerobic stages support nitrogen removal and organic matter breakdown. The MBR membrane provides the final solid-liquid separation.
The extra anaerobic stage makes A²/O-MBR useful for projects with stricter nitrogen and phosphorus removal needs. We position our A²/O-MBR series for municipal treatment, larger residential developments, and projects with strict water-reuse targets. The A/O-MBR system is the simpler option when the main goal is domestic sewage treatment and removal of organic matter and nitrogen.
However, the performance of either system depends on the wastewater, process design, and operating conditions. A system should not be chosen based on its name alone. The wastewater analysis, discharge rules, nutrient targets, and reuse needs all matter.
Both systems are available within our containerized wastewater treatment range and benefit from a compact containerized design. They reduce the need for large-scale civil construction. They can also be supplied in modular formats for different treatment capacities. Neither system removes the need for further treatment in every case. For example, reverse osmosis may be needed if the recovered water must meet stricter dissolved-solids or industrial reuse requirements.
The choice between A/O-MBR and A²/O-MBR should be based on the project's actual needs. We can use wastewater analysis, discharge regulations, nutrient removal targets, and reuse goals to recommend the right configuration.
We offer several membrane technologies for water purification and wastewater treatment through our containerized membrane separation technology range. Our range includes reverse osmosis, nanofiltration, ultrafiltration, MBR, TMBR, DTRO, and STRO membranes. Each membrane is used for a different purpose. The right choice depends on the pollutants in the water and the quality needed after treatment. We can supply membranes as individual products or as part of a complete treatment system.
Reverse osmosis is used when high removal of dissolved salts and contaminants is needed. It uses pressure to push water through a semi-permeable membrane. The membrane holds back many dissolved substances. RO is commonly used for seawater desalination, brackish water treatment, and industrial water purification. Nanofiltration also uses membrane separation. However, it works differently from RO. It is useful when certain dissolved substances, including divalent ions, need to be removed.
Ultrafiltration is mainly used to remove suspended solids, colloids, bacteria, and other larger particles. It is often used as a pretreatment step. It can protect downstream equipment from fouling and damage. It can also be part of a wider water purification process. An ultrafiltration system can be used alongside reverse osmosis when a project requires multiple treatment stages.
MBR and TMBR are membrane technologies used in wastewater treatment. MBR combines biological treatment with membrane filtration. It helps remove organic matter and suspended solids. TMBR is part of our integrated membrane treatment options. It can be used in more complex wastewater systems.
We also offer DTRO and STRO membranes for specialized separation needs. DTRO means disc-tube reverse osmosis. It is useful for difficult wastewater such as landfill leachate and high-salinity industrial effluent. Its disc-tube design is made for challenging feed-water conditions. STRO is another specialized reverse osmosis option. It is used for demanding separation and concentration applications.
The choice of membrane should not depend on the technology name alone. The feed water, salinity, suspended solids, operating pressure, fouling risk, and required water quality all matter. Some projects may need UF, NF, and RO together. Others may need biological treatment through MBR or specialized membranes such as DTRO.
We can combine the right technologies into a custom industrial water purification system or containerized treatment plant. This allows the system to address the real water quality challenge. It avoids relying on one membrane to do every job.
Tel: +86 13370035529
Business What's App: +86 13636655908
E-mail: qilee@qileegroup.com
Add: No. 351 Wenqu Road, Fengxian District, Shanghai