Industrial wastewater projects can be challenging because multiple stages of wastewater treatment, control, utilities, sludge handling and changing wastewater influent conditions need to work together. Integrated Modular Systems (IMS) are a solution to this challenge because they integrate the processes selected to treat wastewater into a coordinated, modular, prefabricated treatment train.
Rather than designing and installing all of the processes at the project site, pumps, piping, instruments, dosing systems, membranes and controls can be arranged on skids or within containerized packages. The configuration will be based on the quality of wastewater to be treated, effluent quality, available area, and the final discharge or reuse destination.
QILEE's product line consists of modularized membrane treatment, chemical treatment, solid-liquid separation, sludge treatment and containerized wastewater treatment equipment.
An integrated modular wastewater treatment system is a collection of treatment units which are coordinated and placed on skids, frames, or containers. Each module carries out a specific, well-defined function and the piping, instrumentation, controls and interfaces are configured to enable the modules to interoperate.
"Modular" refers to the system architecture, NOT the treatment technology. A project can involve any or all of the following: physical separation, chemical conditioning, biological treatment, membrane filtration and sludge dewatering. A different project could require 2 or 3 of those phases.
Some wastewater contains solids, oil, colloids, or solids that are hard to settle and may require a pretreatment process before biological or membrane treatment. They may involve screening, pH adjustment, coagulation, flocculation, dissolved air flotation or clarification, depending on the water quality of the wastewaters involved.
Chemical dosing modules take care of reagent preparation and dosing control. Dissolved air flotation (DAF) may be suitable for removing light solids, oils and flocs which are not settling efficiently, while lamella clarification may be suitable for heavier settleable solids.
This stage also acts as a filter to prevent downstream processes from being subjected to inappropriate solids and loads.
Biological treatment can be the central part of the treatment process if biodegradable organic material is the primary problem. Membrane bioreactor systems are a combination of biological treatment and membrane separation and are appropriate when the need arises for a compact solids separation system and a uniform quality of treated water.
In some instances, fine suspended material can be removed from water after the upstream treatment via ultrafiltration (UF) or before it is treated with RO. Reverse osmosis comes into play when small dissolved constituents (such as salts) have to be reduced to a specific reuse or process-water target.
Modular approach means each technology can be used because it is a solution to a specific treatment issue instead of every project having to follow the same series of steps.
Treatment is just the beginning when it comes to wastewater, as sludge and other residuals from the main treatment process still need to be managed. Sludge can be produced by chemical precipitation or biochemical treatment or as a by-product of membrane processes (concentrate or backwash stream).
Thickening, conditioning, dewatering, storage, or disposal must be considered for a complete design. QILEE also offers polymer preparation equipment, belt filter press equipment, screw press sludge dewatering equipment, sludge thickeners, and other solid-liquid separation equipment.
The incorporation of the handling of residuals early in the design ensures a common design pitfall isn't to be encountered—treated water with no realistic idea about what to do with the solids that remain.
|
Design Factor |
Integrated Modular System |
Conventional Site-Built Plant |
|
Equipment assembly |
With most built on skids or in containers. |
The majority of the components have been fabricated at the construction site. |
|
Site work |
Foundations, utilities, connections and commissioning |
More field fabrication and construction |
|
Expansion |
If interfaces and hydraulics permit, additional modules can be added. |
Larger civil modifications may be needed for expansion. |
|
Layout |
Compact and repeatable |
Increased flexibility with civil custom layouts. |
|
Relocation |
Some skid or container units can be moved |
Typically a fixed facility |
|
Best suited to |
Phased, remote, constrained or retrofit projects |
Large permanent plants with lot of civil works |
Neither of these is necessarily superior. If the required capacity is a large permanent building, then conventional building methods may be appropriate. Modular treatment is more appealing when space, staged capacity, repeatability, or integration with an existing plant are important considerations.
Wastewater from manufacturing processes may include suspended solids, oils, dissolved pollutants, nutrients, or high organic loads or any combination of these. Modular systems enable the engineers to use just the processes necessary for that wastewater and not necessarily one package to deal with all the contaminants.
Remote locations, such as industrial facilities, temporary operations and places without centralized sewers, may not be able to support large plant construction. Skid-mounted or containerized equipment can minimize the need for on-site fabrication.
Production has been altered or effluent requirements have become more stringent so the existing plant needs to be upgraded or a new polishing stage installed. Sometimes, a module, or a small unit, can be installed on a treatment train that is appropriate without the need for replacing the entire treatment train.
In addition to the main stages of wastewater treatment, where treated wastewater will be reused, the process may require an additional stage of filtration or membrane treatment. The appropriate technology should be selected based on the intended reuse specification, not just because advanced treatment is available.
Representative wastewater data should be the first consideration for equipment selection. Peak flow, in addition to the average flow, plus contaminant concentration fluctuations can be factors in whether a process is stable.
When selecting equipment, consider:
These factors dictate if the system requires equalization, chemical treatment, biological treatment, membranes, solids separation or some combination of all these methods. They also impact tank size, pump duty, the capacity to dose, membrane loading, and control needs.
The benefit of modular engineering isn't just less equipment. It's having a clear understanding of process boundaries and making appropriate process links that are consistent with the wastewater being treated.
Integrated modular systems are most applicable when a wastewater project requires multiple coordinated stages of treatment, limited space, staged expansion, site limitations or integration with existing systems.
Their value lies in the ability to match the individual modules with the treatment objective—pretreatment for solids and oils, biological treatment for biodegradable loads, membranes for finer separation, and sludge equipment for the sludge generated in the process. That is more reliable than picking equipment first and figuring out how to fit it to the wastewater.
The descriptions of these processes in QILEE's Integrated Modular Systems may serve as a useful reference for available modular treatment equipment and configurations. Still, present conditions, operating needs, and the quality of treated water needed should be the basis for the final system.