The language associated with water reuse can sometimes be confusing, as “recycled water” and “reclaimed water” are used interchangeably to describe the basic concept: treated used water can be reused for other purposes. In reality, depending on the industry, water sources, local regulations, and treatment goals, these terms can refer to different ways of reusing water.
A water reclaim system must take account of the contaminants entering the plant, the contaminants that have to be removed, and the quality water must meet at the reclaimed water point of use. Recycled water is generally used for municipal sewage, industrial effluent, greywater, or other wastewater that has been treated and re-used in a reclaimed water system or water reused within an industrial process.
A water reclaim system is designed to treat wastewater so it can be reused for a specific beneficial purpose instead of being discharged. The biological treatment, clarification, membrane separation, reverse osmosis, disinfection, or other polishing steps may be used, depending upon the source.
The treated water can be used for irrigation, industrial washing, cooling, process water or any other approved non-potable use. The type of destination determines the type of treatment train to be implemented.
The containerized reclaimed water systems offered by QILEE are based on the combination of different technologies, including membrane bioreactor treatment, ultra filtration, reverse osmosis, etc., to be set up in modular compositions for municipal, industrial, greywater and rainwater reuse projects.
The recycled water system is a larger concept. It holds water once it has been used, processes it as needed and returns it to service. The water can stay within the same facility instead of being treated in a typical wastewater reclamation plant.
A factory, for instance, can recycle rinse water from a production process and remove suspended materials or dissolved constituents from the rinse water before using it for pre-washing.
Depending on the strength of the wastewater, its treatment can involve a single or multiple phases of filtration and disinfection for relatively clean water, or biological treatment, membrane filtration, desalination, or other combinations of treatments.
The two terms are not exactly synonymous technically; there is no universal technical line of distinction between them. They're used interchangeably in some regulations and industries.
|
Aspect |
Recycled Water System |
Reclaimed Water System |
|
Meaning |
General term used for treated and used water, the treatment and reuse of water |
Commonly refers to wastewater treated for a specified beneficial reuse |
|
Typical source |
Water for processes, rinsing, cooling, greywater and wastewater. |
Municipal sewage or industrial effluent, greywater or other wastewater sources |
|
Reuse pattern |
Typically within a facility or internal production loop |
Typically sent to a specific reuse project post-treatment |
|
Treatment level |
Determined by contamination and the next process |
Depends on the quality of the water entering the system and the desired quality of the reclaimed water |
|
Typical applications |
Water for washing, cooling, process reuse, utility water |
Irrigation, industrial reuse, municipal non-potable reuse |
|
Design priority |
Avoid spoiling the receiving operation; "recover" useful water. |
Generate reusable quality water. |
Practical means useful. Recycling is basically aimed at retaining water in the cycle, whereas reclamation is typically aimed at the reclaimed water being fit for reuse in a controlled application.
Water analysis should be the first step in specifying a reuse treatment train, not the label “recycled” or “reclaimed.” If the contaminant profile is different for two sites receiving the same daily flow, different equipment is required.
Coarse solids, suspended matter, oil or other materials that might interfere with subsequent operations may be removed by pretreatment. If wastewater contains biodegradable organic matter and/or nutrients, biological treatment can be employed prior to final polishing.
MBR systems are biological systems with the membrane solid-liquid separation mechanism that results in clarified effluent without a traditional secondary settling tank. By using ultrafiltration, it is possible to get rid of fine suspended and colloidal material. If the re-use target requires much lower dissolved salt levels, then RO can be installed after appropriate pre-treatment.
As part of QILEE's containerized reclaimed-water product portfolio, combinations are offered, for instance, MBR and UF+RO, and the process arrangement can be adjusted to the wastewater source and desired output.
Water can be recycled in manufacturing when it is reused in the same step of the process without compromising its water quality requirements or the quality of the end use. Depending on contaminant and production needs, rinse water, wash water, selected utility water streams and appropriately treated process wastewater can all be candidates.
The term “reclaimed water” is more frequently used for municipal or decentralized projects. To prevent discharge of treated sewage or greywater, it can be used for irrigation, landscaping, or other allowable non-potable uses.
Containerized treatment can also be utilized at remote sites and locations that do not have a large centralized treatment facility, with equipment installed inside a transportable module. QILEE provides containerized reclaimed-water solutions for decentralized, municipal, and industrial reclaimed-water applications.
First, don't ask if you need a recycled-water plant or a reclaimed-water plant. Four engineering questions to begin with: What is the feed water? What is the amount available? What quality is needed post-treatment? What purpose(s) will the treated water be put to?
Average and peak flow, suspended solids, organic load, salinity, nutrients, oils, metals, temperature, pH, and process-related contaminants should be considered during the design review. Water quality may also be different depending on shift, production schedule, season or cleaning schedule, and thus a grab sample may not reflect design conditions.
The treatment boundary is represented by the reuse target. The quality of water returned to an early washing operation may not be as high as the water input to a sensitive process, and there are significant differences in quality required for irrigation versus high-purity industrial reuse.
These decisions affect membrane selection, membrane pretreatment, recovery rate, chemical requirement, concentrate disposal, sludge generation, cleaning frequency, instrumentation, and operating cost. The reuse specification is met consistently with a sound system, without the addition of treatment stages where there is no practical benefit.
The distinction between a recycled water system and a reclaimed water system is primarily one of context, not a fixed technological division. Reclaimed water is often used more specifically for wastewater treated for defined reuse, while recycled water can be used more broadly for internal process reuse as well as other reuse applications.
It is therefore essential that a successful water reclaim system be specified based on the source-water data and on the requirement for reuse. Based on those conditions, reclaimed water systems can apply biological treatment, MBR, UF, RO, disinfection, or a specific combination.
The question for the buyer (and the engineer) is not, “Is it a ‘recycled' or ‘reclaimed' system?” but whether the proposed treatment train will be able to sufficiently treat the available wastewater to the point that it can be used for its next purpose.
Tel: +86 13370035529
Business What's App: +86 13636655908
E-mail: qilee@qileegroup.com
Add: No. 351 Wenqu Road, Fengxian District, Shanghai